SynovaDIGITAL
Free tool · HVAC, plumbing & electrical

AC Size Calculator

How many BTUs and tons does a space need to stay cool? This estimator turns square footage, climate, ceiling height and sun into a cooling load and a system size, for HVAC contractors and homeowners comparing replacement bids.

Free, no sign-up. Runs in your browser; nothing you type is stored unless you choose to email yourself the results.

AC size (BTU & tons) estimator

Loading calculator…

Email me these results. We'll send your numbers, plus how to turn this calculator into a lead magnet on your own website.

How to use it

Three steps, about a minute

  1. Step 1

    Type the Area to cool, counting only the conditioned rooms this system will serve.

  2. Step 2

    Pick a Climate and a Sun exposure, and change Ceiling height if the rooms aren't 8 ft.

  3. Step 3

    Read the Estimated cooling load in BTU/h and the Nearest system size in half-ton steps.

How the ac size calculator works

The base is a rule of thumb: 20 BTU per hour for every square foot. Three adjustments follow. Climate multiplies the load by 0.9 for cool northern areas, 1.0 for moderate and 1.15 for hot southern areas. Ceiling height ÷ 8 scales it for taller rooms holding more air. Sun exposure applies 0.9 for mostly shaded, 1.0 for average and 1.1 for very sunny. Dividing the load by 12,000, the BTU/h in one ton of cooling, and rounding to the nearest half gives the system size. The default 1,800 sq ft in a moderate climate, 8 ft ceilings and average sun comes to 36,000 BTU/h, which is 3 tons. Insulation, window area, duct leakage and the number of occupants are not in this math. Before you size equipment you'll install, run a Manual J load calculation.

Example inputs
Area to cool1,800 sq ft
ClimateModerate
Ceiling height8 ft
Sun exposureAverage
Results
Estimated cooling load36,000 BTU/h
Nearest system size3 tons
Per square foot20 BTU

Rule of thumb of about 20 BTU per square foot, adjusted for climate, ceiling height and sun. A Manual J load calculation is the professional standard.

btu calculator for air conditionerwhat size ac unit do i needac tonnage calculator
Pro tips

Using the numbers like a pro: tips for HVAC contractors

Tip 01

Use this number to start the conversation, not to pick the unit. Offering a Manual J with every replacement quote separates you from bids that simply match the old unit's tonnage.

Tip 02

When a customer asks to go bigger just to be safe, explain short cycling. An oversized unit shuts off before it pulls moisture out, leaving rooms cool but clammy.

Tip 03

Quote good, better and best options at the same tonnage, changing efficiency and features rather than size. Customers compare like for like, and you avoid a race to the cheapest box.

Turn it into leads

Put a calculator like this on your own website

Someone searching for AC sizes is often replacing a system or doubting a quote they already have. A sizing tool on your cooling page answers the question on the spot, then offers a free in-home load calculation for a phone number and address. That converts a curious visitor into a booked estimate. If you want one on your site, we build them to match your brand and service area.

Free, founder-reviewed

Get a free audit of your marketing

Website, Google Business Profile and a Google Maps rank scan across your area. Plain English, no obligation.

FAQ

AC Size Calculator questions

What size AC do I need for 1,800 square feet?

Using the common rule of thumb of 20 BTU per square foot, 1,800 sq ft needs about 36,000 BTU/h, which is a 3-ton system. Hot climates, very sunny rooms or tall ceilings push that up, and a tight, well-insulated home may need less. A Manual J load calculation gives the real answer for a specific house.

How many BTU is a ton of air conditioning?

One ton of cooling equals 12,000 BTU per hour, a unit that traces back to the heat needed to melt a ton of ice in 24 hours. A 2-ton system is 24,000 BTU/h, a 3-ton is 36,000 BTU/h and a 5-ton is 60,000 BTU/h. Home systems are typically sold in half-ton steps.

What is a Manual J load calculation?

Manual J is the ACCA procedure for calculating a home's heating and cooling loads room by room. It accounts for insulation, window size and orientation, air leakage, duct location, local design temperatures and occupants. Many jurisdictions reference it in code, and it is the standard way to avoid oversizing or undersizing equipment.

Get new free tools as we build themOne short email a month with a new calculator or checklist for local service businesses. Unsubscribe any time.
Free audit + map-rank scan

See exactly why competitors get your calls.

Tell us where you work. You'll get a plain-English audit of your website and Google Business Profile, plus a heat map of where you rank on Google Maps, block by block. Free, with no obligation.

Free audit + map-rank scanSee where you rank, block by blockMonth-to-monthNo long-term contractDeliverables guaranteeMiss the agreed work, that month's fee is refunded
Free, no obligation. We aim to reply within one business day.
ToolsFree audit